Jul 25, 2019 Leave a message

VACUUM PUMP TROUBLE SHOOTING

timg

 

Trouble

Possible reason

Solution

Pump can not be started

1.Out of electrical

1.Check the connection of power supply

2.Operation voltage is abnormal

2.Voltage wave within 10%

3.Motor is malfunctioning

3.Replace the motor

4.Pump is jammed

4.Repair the pump

5.Out of operation for long, liquid and organic solvents result rust of the pump body

5.Repair the pump

6.Pump inner accessories are damaged

6.Repair the pump

Pump can not reach the maximum pressure

1.Pump is too small to suit for the machine

1.Replace the pump

2.Measuring technique or gauge is unsuitable

2.Use the correct measuring technique and gauge,measure the pressure directly at pump's intake port.

3.Oil level is too low

3.Add Oil

4.Vacuum system leak

4.Check the leakage(sealing element)

5.Exhaust valve is malfunctioning

5.Repair the valve

6.Lubricate seal oil channel inside pump blocked

6.Clean oil channel

7.Oil is unsuitable or deteriorated

7.Change the oil(Pump Oil only)

Oil seal leak

1.Oil seal broken

1.Replace new oil seal

2.Seal ring was deformed

2.Replace new seal ring

Abnormal voice

1.Motor is malfunction

1.Voltage wave within 10%

2.Coupling element is worn

2.Install new coupling element

3.Vane spring is broken

3.Replace the vane spring

4.Foreign material into the pump

4.Clean the pump body

5.Parts of screw loosed

5.Check the parts and tighten the screw

Overtemperature

1.Continuous operation under high pressure in the intake port

1.Shorten exhaust time as far as possible

2.Process gas is too hot

2.Set up something like cold trap

3.Cooling air supply is obstructed

3.Set pump correctly

4.Oil cycle is obstructed

4.Clean the oil channels

5. Ambient temperature is too high

5.Cooling the temperature

Oil injection

1.Too much oil in the pump

1.Drain some oil

2.Continuous operation under high pressure in the intake port

2.Shorten exhaust time as far as possible

Oil drain back

1.Misalignment between the check valve and the inlet opening

1.Reset them

2.Misalignment of exhaust valve

2.Reset it

3.Impurities in the exhaust valve ports

3.Clean the impurities

 

 

 